103950 Measurement of maprotiline and oxaprotiline in plasma by HPLC of fluorescent derivatives
Home
sorbtech.com
Back
Contact an Account Manager
Measurement of maprotiline and oxaprotiline in plasma by HPLC of fluorescent derivatives
Summary
Type:
HPLC
Application #:
103950
Detection:
fluorescence, excitation 365nm, emission 420nm
Conditions:
eluent: hexane - abs. ethanol (95:5, v/v)
flow rate 1.8ml/min
Authors:
Breyer-Pfaff U
Source:
J Chromatogr 309 (1984) 107 - 114
Details
Legend: Fig. 1. HPLC fluorescence records obtained upon maprotiline analysis in 1ml plasma A) blank plasma B) blank plasma spiked with 10ng maprotiline and 400ng oxaprotiline (int. std.) C) plasma from a p